• 01 How to resolve Excitation Mode Alarm of Electromagnetic Flow Meters?

    When the Electromagnetic Flow Meter shows Excitation Alarm, the user is encouraged to check; 1) whether EX1 and EX2 are open circuit; 2), whether the total sensor excitation coil resistance is less than 150 OHM. Users are recommended to contact factory for assistance if excitation alarm goes off.

  • 02 How to resolve inaccurate flow of Electromagnetic Flow Meters?

    If the Electromagnetic Flow Meter is showing inaccurate flow, the user is should check following conditions before contacting factory. 1), Check if the liquid is full pipe; 2) Check conditions of signal lines; 3), Modify sensor parameters and zero-point to the values shown on label. If the error persists, users should contact factory to make proper arrangements for the meter.

  • 03 How many connections types of turbine?

    Turbine has various connection types for choosing,like Flange type,Sanitary type or Screw type,ect.

  • 04 Metal tube rotameter can be used for what kind of fluid?

    Metal tube rotameter can be used for clean liquid,it has advantages of stable working and high accuracy up to 0.5%;

  • 05 Electromagnetic flow meter conductivity request

    More than 5μs/cm, suggest conductivity is more than 20μs/cm

  • 06 Electromagnetic flow meter flow velocity range

    0.1-15m/s, suggest velocity range is 0.5-15m/s to ensure good accuracy